Non-pyrogenic 0.22/0.45 μm Pore Size Sterile Syringe Filters
·Non-pyrogenic 0.22/0.45 μm Pore Size Sterile Syringe Filters
·We have a wide range of diameters available 13, 25, 30mm: the right size for the right volume or particle load
·High flow rate, high throughput, shorten filtration time
PES has low protein adsorption and good hydrophilicity
·Equipped with PES membrane: Provides >98.5% protein recovery
Pre-sterilized: It can be used for sterile filtration and clarification of biological fluids
Description
Products Description
Feature:
· Non-pyrogenic 0.22/0.45 μm Pore Size Sterile Syringe Filters
· We have a wide range of diameters available 13, 25, 30mm: the right size for the right volume or particle load
· High flow rate, high throughput, shorten filtration time
· PES has low protein adsorption and good hydrophilicity
· Equipped with PES membrane: Provides >98.5% protein recovery
· Pre-sterilized: It can be used for sterile filtration and clarification of biological fluids
· Pyrogen-free, low extractables and surfactant-free ensuring filtrate purity
· Excellent throughput, for faster filtration and more process volume
· Gamma radiation sterilized
· Individually packaged to prevent cross contamination
It can be used in:
· Sterile filtration and clarification of biological fluids.
· Tissue culture media preparation.
· Protein and enzyme filtration.
· Hybridization buffers.
· Other aqueous solution.


Ordering Information
| Cat # | Membrane | Pore size(μm) | Diameter(mm) | Description | Unit | Total |
| 08-PES1322R | PES | 0.22 | 13 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 8 Packs/Case | 800 |
| 08-PES2522R | PES | 0.22 | 25 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 4 Packs/Case | 400 |
| 08-PES3022R | PES | 0.22 | 30 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 4 Packs/Case | 400 |
| 08-PES3322S | PES | 0.22 | 33 | Double luer lock. Individually packed. | 100 Pcs/Pack, 4 Packs/ Case | 400 |
| 08-PES3345S | PES | 0.45 | 33 | Double luer lock. Individually packed. | 100 Pcs/Pack, 4 Packs/ Case | 400 |
| 08-PES3322M | PES | 0.22 | 33 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 4 Packs/ Case | 400 |
| 08-PES3345M | PES | 0.45 | 30 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 4 Packs/ Case | 400 |
| 08-CA3022R | CA | 0.22 | 30 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 4 Packs/ Case | 400 |
| 08-CA3045R | CA | 0.45 | 30 | Female luer lock + male luer slip. Individually packed. | 100 Pcs/Pack, 4 Packs/ Case | 400 |
Biologix, a manufacturer and supplier of laboratory products, has a Class 100,000 clean room and a R&D testing laboratory certified by ISO9001, CE and FDA. Biologix is committed to producing and delivering high-quality products, providing innovative solutions to numerous labs around the world.
Biologix focuses on the R & D and innovation of core products, and has the standard class 100,000 clean room which are compliant with GMP standards and number of professional R & D testing laboratories which are all ISO 9001, CE, and FDA registered, and follow the strict CDC guidelines for purity and efficiency. Biologix is committed to the design and manufacture of high-quality products, enriching product lines, and strengthening the service of complete solutions.

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. How can I place a product order?
Placing an order for a product is simple. You can visit out shop site(www.biologixgroup.com) and place an online order. Or if you have questions, would like to discuss an order with a representative, you can contact us directly and our service associates will answer your questions and help place your order.
3. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
4. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.
Hot Tags: non-pyrogenic 0.22/0.45 μm pore size sterile syringe filters manufacturers, suppliers, factory, price
Send Inquiry