Home - Products - PCR Consumables - Details
0.1/0.2ml DNase & RNase 8-Strip PCR Tubes
video
0.1/0.2ml DNase & RNase 8-Strip PCR Tubes

0.1/0.2ml DNase & RNase 8-Strip PCR Tubes

·DNase & RNase 8-Strip PCR Tubes
·Two volumes: 0.1 and 0.2ml are available
·Material: prime virgin polypropylene

Description

 

Products Description

Feature:

● DNase & RNase 8-Strip PCR Tubes, all products are non-sterile

● Material: prime virgin polypropylene

● Domed caps will transfer heat faster than normal PCR tubes

● Flat caps are ideal for real-time PCR (qPCR)

● Single PCR tube has high transparency and a very thin tube wall, making it easy to observe and conduct heat during the experiment

● Special cap design can prevent opening during cycling and incubation

● 8-strip PCR tubes are DNase, RNase, and endotoxin free

Those with attached caps offer the option of opening and closing the tubes independently to prevent sample contamination

● Working Temperature: stable from -20ºC to 100ºC

● Autoclavable

● Universal fits for the PCR instrument; withstand centrifugation of 6,000 RCF in a fully supported rotor

● Products will be carefully packaged and transported, we will also provide quality after-sales service, welcome to buy!

* Assorted colors for 8-Strip PCR tubes should be ordered separately

 

0.2ml DNase & RNase 8-Strip PCR Tubes

 0.1 ml DNase & RNase 8-Strip PCR Tubes

 

Ordering Information

Cat# Volume(ml) Color Autoclavable Cap Type Packaging Total
60-0088 0.2 Clear Yes Flat Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0188 0.2 Pink Yes Flat Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0388 0.2 Blue Yes Flat Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0488 0.2 Yellow Yes Flat Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0008 0.2 Clear Yes Domed Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0108 0.2 Pink Yes Domed Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0208 0.2 Green Yes Domed Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0308 0.2 Blue Yes Domed Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0408 0.2 Yellow Yes Domed Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-1088 0.1 Clear Tubes, Clear Caps Yes Flat Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-1088W 0.1 White Tubes, Clear Caps Yes Flat Cap 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case 1250 Sets/Case
60-0288 0.2 Clear Yes Flat Cap 120/Unit, 10 Units/Case 1200/Case

 

Biologix, a manufacturer and supplier of laboratory products, has a Class 100,000 clean room and a R&D testing laboratory certified by ISO9001, CE and FDA. Biologix is committed to producing and delivering high-quality products, providing innovative solutions to numerous labs around the world.

Biologix is specialized in the R & D and production of disposable medical detection reagents & supplies, laboratory supplies & instruments, and complete biobanking solutions. It has the standard class 100,000 clean room which are compliant with GMP standards and number of professional R & D testing laboratories which are all ISO 9001, CE, and FDA registered, and follow the strict CDC guidelines for purity and efficiency. Biologix is committed to the design and manufacture of high-quality products, enriching product lines, and strengthening the service of complete solutions.

3d96e3d9b23e93aee63f7db4d90b561

FAQ

1. What are the main factors that influence the maximum centrifugal acceleration force?

Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?

To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.

Hot Tags: 0.1/0.2ml dnase & rnase 8-strip pcr tubes manufacturers, suppliers, factory, price

You Might Also Like

Shopping Bags