Low Retention Filter Tips 10ul Filter Tips Sterilization Laboratory Consumables
filter tips 10ul filter tips sterilization Laboratory Consumables
Description






Characteristic
1. Made in Bioclean room.
2. Extremely straight low retention tips ensure accurate and precise sample.
3. Extra-long tips: 10μl with max volume 20μl, 200μl with max volume 300μl, and 1000μl with max volume 1250μl.
4. Racked filter tips, sterile.
5.DNase & RNase free, non-pyrogen.
6. User-friendly label on the tip rack.
7. Materials: Tips are made of PP, filters are made of UHMWPE with pore size 0.22um.
8. Tips all are natural clear color
Order Information
Cat. No. | Description |
23-0011S | 0.1µl-10µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case |
23-0021S | 1µl-20µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case |
23-0051S | 1µl-50µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case |
23-0101S | 1µl-100µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case |
23-0201S | 1µl-200µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case |
23-1001S | 100µl-1000µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case |

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use
of organic solutions, temperature below 0°C, centrifuging without
centrifuge adapter, etc. Conduct a trial run to determine proper
conditions before any critical use begins.
The
RCF (relative centrifugal force) or G ratings for our disposable
centrifuge tubes have been established at room temperature using tubes
filled to nominal capacity with water and centrifuging for 30 minutes.
recommended carriers, adapters, and cushions that fully support the
tubes. If an angle head rotor is used or proper support is not provided,
G values will be lower.
Do
not confuse speed or revolutions per minute (RPM) with relative
centrifugal force (RCF). Instructions for centrifuging a sample at a
given RPM and time are incomplete unless the rotor or radius is
specified. Protocols should always state the time and RCF value for
centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To
ensure successful steam sterilization of your plastic labware please
adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS
ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm
for 15 minutes. Do not use a dry cycle, as this may cause deformation
or weakening of the plastic. Allow temperature within the autoclave to
return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We
look at quality from every angle in terms of functionality, safety,
purity, formulation, consistency, manufacturing, customer service,
technical support, and much more. According to the detailed QA/QC
procedures for our manufacturing facility, each and every product is
traceable by lot, regardless of packaging format. Products must go
through a five-step human inspection before being released for
packaging. Biologix applies the most stringent standards to certify that
products are free from RNase, DNase, endotoxin (pyrogens), etc. In
addition to being ISO 9001:2008, CE compliant, we also make available to
our customers lot-specific certificates such as Sterilization
Certificates, Nuclease Free Certificates, Certificates of Origin, etc.